1.
J Radiol Prot ; 43(1)2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-36731124

RESUMO

INTRODUCTION: complex fluoroscopy-guided interventional procedures in cardiology are known to result in higher radiation doses for patients and staff. PURPOSE: to estimate the equivalent dose received in different regions of the cardiologist's body in catheterism (CATH) and percutaneous coronary intervention (PCI) procedures, as well as to evaluate the effectiveness of monitoring the doses in the catheritization laboratory (cath lab) using a direct ion storage dosimeter. MATERIALS AND METHODS: the InstadoseTMand the thermoluminescent dosimeters (TLD-100) were fixed simultaneously in the following regions of the cardiologist's body: near the eyes (left and right), the trunk region (over the lead apron) and the left ankle. Occupational doses were recorded during 86 procedures (60% CATH). RESULTS: catheterization procedures showed third quartile dose values near to the left eye region equal to 0.10 mSv (TLD-100) and 0.12 (InstadoseTM) and for intervention 0.15 mSv (TLD-100 and InstadoseTM). The doses measured in the trunk region, over the lead apron, were about 13% higher for catheterization procedures and 20% higher for intervention procedures compared to left eye region measurements. The Wilcoxon-Mann-Whitney test was applied for unpaired data for all body regions, comparing the data obtained between the TLD-100 and InstadoseTMdosimeters. For CATH and PCI, the responses of the TLD-100 and InstadoseTMdosimeters are considered equal for all analysed regions (p> 0.05) with the exception of the right eye region. CONCLUSION: the InstadoseTMpassive dosimeter can be useful as a complementary assessment in the monitoring of a cardiologist's personal occupational doses in the cath lab.


Assuntos
Cardiologistas , Exposição Ocupacional , Intervenção Coronária Percutânea , Exposição à Radiação , Humanos , Dosímetros de Radiação , Doses de Radiação , Exposição Ocupacional/análise , Exposição à Radiação/análise
2.
Arq. bras. cardiol ; 112(4): 392-399, Apr. 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001281

RESUMO

Abstract Background: Posterior subcapsular cataract is a tissue reaction commonly found among professionals exposed to ionizing radiation. Objective: To assess the prevalence of cataract in professionals working in hemodynamics in Brazil. Methods: Professionals exposed to ionizing radiation (group 1, G1) underwent slit lamp examination with a biomicroscope for lens examination and compared with non-exposed subjects (group 2, G2). Ophthalmologic findings were described and classified by opacity degree and localization using the Lens Opacities Classification System III. Both groups answered a questionnaire on work and health conditions to investigate the presence of risk factors for cataract. The level of significance was set at 5% (p < 0.05). Results: A total of 112 volunteers of G1, mean age of 44.95 (±10.23) years, and 88 volunteers of G2, mean age of 48.07 (±12.18) years were evaluated; 75.2% of G1 and 85.2% of G2 were physicians. Statistical analysis between G1 and G2 showed a prevalence of posterior subcapsular cataract of 13% and 2% in G1 and G2, respectively (0.0081). Considering physicians only, 38% of G1 and 15% of G2 had cataract, with the prevalence of posterior subcapsular cataract of 13% and 3%, respectively (p = 0.0176). Among non-physicians, no difference was found in the prevalence of cataract (by types). Conclusions: Cataract was more prevalent in professionals exposed to ionizing radiation, with posterior subcapsular cataract the most frequent finding.


Resumo Fundamento: A catarata subcapsular posterior é uma reação tecidual encontrada com frequência nos profissionais expostos à radiação ionizante. Objetivo: Avaliar a prevalência de catarata nos profissionais que atuam na área de hemodinâmica no Brasil. Métodos: Profissionais expostos à radiação ionizante (grupo 1, G1) foram submetidos ao exame biomicroscópico com lâmpada de fenda para avaliação do cristalino, e comparados aos não expostos (grupo 2, G2). Os achados foram descritos e classificados quanto ao grau de opacidade e localização por meio do Lens opacities classification system III. Ambos os grupos responderam questionário sobre condições de trabalho e de saúde para afastar fatores de risco para catarata, e foram comparados quanto aos achados. Foi utilizado um nível de significância de 5% (p < 0,05). Resultados: Foram avaliados 112 voluntários (G1) com média de idade 44,95 (±10,23) anos e 88 voluntários (G2) com média de 48,07 (±12,18) anos. Desses, 75,2% (G1) e 85,2% (G2) eram médicos. A análise estatística entre os grupos G1 e G2 mostrou uma prevalência da catarata no grupo G1 de 33% comparada ao G2 de 16% (p = 0,0058), sendo a catarata subcapsular posterior presente em 13% no G1 e 2% no G2 (p = 0,0081). Considerando apenas os médicos, 38% no G1 e 15% no G2 (p = 0,0011) apresentaram catarata, sendo a subcapsular posterior 13% e 3% (p = 0,0176), respectivamente. No grupo dos profissionais não médicos, não houve diferença estatisticamente significativa na prevalência dos achados oftalmológicos. Conclusões: A catarata esteve mais presente no grupo de profissionais expostos à radiação ionizante, sendo que a catarata subcapsular posterior foi o dano tecidual mais encontrado.


Assuntos
Humanos , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Catarata/epidemiologia , Exposição à Radiação/efeitos adversos , Cardiologistas/estatística & dados numéricos , Cristalino/efeitos da radiação , Doenças Profissionais/epidemiologia , Radiação Ionizante , Catarata/etiologia , Brasil/epidemiologia , Prevalência , Fatores de Risco , Exposição Ocupacional/efeitos adversos , Estatísticas não Paramétricas , Exposição à Radiação/estatística & dados numéricos , Dispositivos de Proteção dos Olhos/estatística & dados numéricos , Hemodinâmica , Doenças Profissionais/etiologia
3.
Einstein (Sao Paulo) ; 17(2): eAO4156, 2019 Mar 18.
Artigo em Inglês, Português | MEDLINE | ID: mdl-30892376

RESUMO

OBJECTIVE: To develop and test a beat-to-beat blood pressure monitoring device during coronary angiography, and compare it with invasive blood pressure monitoring. METHODS: Twenty-eight patients with an indication for hemodynamic study were selected for this investigation, and kept in supine position. Before starting the coronary angiography, they were instructed about the use of the left radial bracelet for beat-to-beat blood pressure monitoring. RESULTS: There was a significant difference between the time required for the catheterization laboratory team to acquire the first invasive blood pressure reading and the time to obtain the first beat-to-beat reading (11.1±5.1 and 1.5±1.8, respectively; p<0.0001). The intraclass correlation coefficients (95%CI) of systolic and diastolic blood pressures were 0.897 (0.780-0.952) and 0.876 (0.734-0.942), indicating good reproducibility. CONCLUSION: This study showed the process to develop a beat-to-beat blood pressure monitoring device. When compared to invasive blood pressure monitoring, there were no significant differences between the two methods. This technique may play a promising coadjuvant role when combined with invasive monitoring during coronary angiography procedures.


Assuntos
Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Angiografia Coronária/métodos , Determinação da Pressão Arterial/métodos , Desenho de Equipamento , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
4.
Arq Bras Cardiol ; 112(4): 392-399, 2019 04.
Artigo em Inglês, Português | MEDLINE | ID: mdl-30810610

RESUMO

BACKGROUND: Posterior subcapsular cataract is a tissue reaction commonly found among professionals exposed to ionizing radiation. OBJECTIVE: To assess the prevalence of cataract in professionals working in hemodynamics in Brazil. METHODS: Professionals exposed to ionizing radiation (group 1, G1) underwent slit lamp examination with a biomicroscope for lens examination and compared with non-exposed subjects (group 2, G2). Ophthalmologic findings were described and classified by opacity degree and localization using the Lens Opacities Classification System III. Both groups answered a questionnaire on work and health conditions to investigate the presence of risk factors for cataract. The level of significance was set at 5% (p < 0.05). RESULTS: A total of 112 volunteers of G1, mean age of 44.95 (±10.23) years, and 88 volunteers of G2, mean age of 48.07 (±12.18) years were evaluated; 75.2% of G1 and 85.2% of G2 were physicians. Statistical analysis between G1 and G2 showed a prevalence of posterior subcapsular cataract of 13% and 2% in G1 and G2, respectively (0.0081). Considering physicians only, 38% of G1 and 15% of G2 had cataract, with the prevalence of posterior subcapsular cataract of 13% and 3%, respectively (p = 0.0176). Among non-physicians, no difference was found in the prevalence of cataract (by types). CONCLUSIONS: Cataract was more prevalent in professionals exposed to ionizing radiation, with posterior subcapsular cataract the most frequent finding.


Assuntos
Cardiologistas/estatística & dados numéricos , Catarata/epidemiologia , Cristalino/efeitos da radiação , Doenças Profissionais/epidemiologia , Exposição à Radiação/efeitos adversos , Adulto , Idoso , Brasil/epidemiologia , Catarata/etiologia , Dispositivos de Proteção dos Olhos/estatística & dados numéricos , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Profissionais/etiologia , Exposição Ocupacional/efeitos adversos , Prevalência , Exposição à Radiação/estatística & dados numéricos , Radiação Ionizante , Fatores de Risco , Estatísticas não Paramétricas
5.
Einstein (Säo Paulo) ; 17(2): eAO4156, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-989777

RESUMO

ABSTRACT Objective To develop and test a beat-to-beat blood pressure monitoring device during coronary angiography, and compare it with invasive blood pressure monitoring. Methods Twenty-eight patients with an indication for hemodynamic study were selected for this investigation, and kept in supine position. Before starting the coronary angiography, they were instructed about the use of the left radial bracelet for beat-to-beat blood pressure monitoring. Results There was a significant difference between the time required for the catheterization laboratory team to acquire the first invasive blood pressure reading and the time to obtain the first beat-to-beat reading (11.1±5.1 and 1.5±1.8, respectively; p<0.0001). The intraclass correlation coefficients (95%CI) of systolic and diastolic blood pressures were 0.897 (0.780-0.952) and 0.876 (0.734-0.942), indicating good reproducibility. Conclusion This study showed the process to develop a beat-to-beat blood pressure monitoring device. When compared to invasive blood pressure monitoring, there were no significant differences between the two methods. This technique may play a promising coadjuvant role when combined with invasive monitoring during coronary angiography procedures.


RESUMO Objetivo Desenvolver e validar um equipamento para monitorização de pressão arterial batimento a batimento, durante a realização de coronariografia, e comparar com as medidas de pressão arterial invasiva obtidas. Métodos Foram selecionados 28 pacientes com indicação de estudo hemodinâmico, que permaneceram em decúbito dorsal horizontal e, antes do início da coronariografia, foram orientados quanto ao uso da pulseira radial esquerda para monitorização da pressão arterial batimento a batimento. Resultados Houve diferença significativa entre o tempo necessário para a equipe de hemodinâmica adquirir a primeira medida da pressão arterial invasiva e o tempo da primeira medida da pressão arterial batimento a batimento (11,1±5,1 e 1,5±1,8, respectivamente; p<0,0001). Os coeficientes de correlação intraclasse (IC95%) da pressão arterial sistólica e da diastólica foram 0,897 (0,780-0,952) e 0,876 (0,734-0,942), indicando boa reprodutibilidade. Conclusão Este estudo demonstrou o processo de desenvolvimento de um equipamento para avaliação da pressão arterial batimento a batimento. Quando comparado com a pressão arterial invasiva, não foram encontradas diferenças significativas entre as duas medidas. Essa técnica pode constituir ferramenta coadjuvante promissora, associada à monitorização invasiva, durante procedimentos de coronariografia.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Determinação da Pressão Arterial/instrumentação , Monitores de Pressão Arterial , Angiografia Coronária/métodos , Determinação da Pressão Arterial/métodos , Reprodutibilidade dos Testes , Desenho de Equipamento , Frequência Cardíaca/fisiologia , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...